Advanced HACH LDO® Process Dissolved Oxygen Probe
Description

Hach’s next generation LDO® (Luminescent Dissolved Oxygen) Probe r ...see more

Specification
  • No Calibration Required
  • No Membranes to Replace
  • No Missed Cleaning Cycles
  • No Drift
  • No Complications
DR6000 Spectrophotometer
Description

The DR6000™ is the industry’s most advanced lab spectrophotometer. It offers high-speed wavelengt ...see more

Specification

 

  • Your Water Testing Needs, All in One Spectrophotometer
  • Accessories for High Volume and High Accuracy Testing Needs
  • Advanced Quality Assurance at Your Fingertips
  • Guided Procedures and Elimination of False Readings
  • Automatically Avoids Errors

Athenea Autonomous Chlorine Analyser
Description

Athenea is an autonomous chlorine analyser for the Water Distribution network.&# ...see more

Specification

 

  • Integrated pH and temperature monitoring gives greater accuracy for amperometric technology.
  • Minimal calibration required with long term reliability.

  • Easy to use graphic calibration interface via PC.

  • Low power consumption electronics optimizing battery life.

  • GSM/SMS communication.

  • Transmits and generates data and alarms.

  • Open protocol that can be integrated into any Scada system.

  • IP68 rating.

AutoCAT 9000 Chlorine Amperometric Titrator
Description

 

Automatic calculation of analyte concentration. Aut ...see more

Specification

 Dimensions (H x W X D): 15 in x 9.1 in x 17.7 in (380 mm x 230 mm x 450 mm)Display Real-time graphics, menu driven, LCD
Electrode: Dual platinum
Languages: English, French, and Spanish
Output: RS-232 Serial output to printer/PC
Power Requirements: /264 Vac, 47/63 Hz, 115 VA
Width US: N/A

Biogas Titration Manager
Description

Biogas Titration Manager for efficient routine analysis process ac ...see more

Specification

Beaker Volumes Accepted: 5 to 400 mL

Burette: Motor Resolution: 18000 steps
Burette: Stand / Tap Type: 1 x 25 mL embedded burette stand included
Burette: Volumes Available: 1 mL, 5 mL, 10 mL, 25 mL & 50 mL
Dimensions (English Units): 18 in x 9 in x 15 in Display: LCD: Graphic 128x128 dot LCD protected from spillages w/TPX cover
GLP Features: Automatic GLP compliant result printouts with optional printer connected Input: Electrode and temperature
PS/2 port for optional PC keyboard and/or barcode reader Languages of User Interface: English, German, Danish, French, Italian, Spanish, Swedish
Measurement Method:
FOS/TAC ratio according to Nordmann method:
-Total Inorganic Carbon TAC
-Volatile Organic Acids FOS
Combined pH & FOS/TAC Measurement Range: -2000 to +2000 mV
mV Resolution: 0.1 mV
Operating Humidity: 20 to 80 % (without water condensation)
 Operating Temperature: 5 to 40 °C
Output: Serial connections printer/PC, balance, sample changer, and additional titrator for use with TitraMaster 85 PC software Password Protection: Up to 10 characters, alphanumeric pH Direct
Measurement: -9 to 23 pH pH Resolution: 0.001 pH Power Requirements: 115 Vac (+/-10%) or 230 Vac (+/- 10%), 50-60 Hz
Sample Changer: Serial RS232 with SAC850
Sample ID: Up to 16 characters, alphanumeric
Sample Stand: Embedded with magnetic stirring Stirring Speed: 0 to 1100 rpm in 50 rpm steps, optional propeller stirrer available
Stored Data: Non-volatile memory storage of the last 60 results & last reagent/electrode calibration
Stored Programs:
Up to 10 user-programmable methods including preprogrammed methods.
Non-volatile memory for storage of last 60 results & last reagent/electrode calibration.
Embedded operating prodecures for burette daily maintenance and reagent exchange operations.
Temperature Range: -10 to 100 °C Temperature Resolution: 0.1 °C TTL Input / Output: 1 Input/1 Output 0-5V
Unit:
Equivalent volumes at end point
TAC in mg/L CaCO₃ (lime reserve)
FOS in mg/L CH₃COOH (acetic acid)
FOS/TAC ratio User ID: Up to 16 characters, alphanumeric Weight: 5 kg (excluding reagent bottles)
User ID: Up to 16 characters, alphanumeric
Weight: 5 kg (excluding reagent bottles)
Hach sensION+ Portable pH, ORP, EC Field Kit
Description

Hach sensION+ Portable pH, ORP, EC Field Kit, an all-in-one system with guided menu navigation ma ...see more

Specification

 Automatic Buffer Recognition: pH 2.01, 4.01, 7.00, 9.21, 10.09
Conductivity Accuracy: ≤ 0.5 % (± 1 digit) of measurement range
Display Type: 128 x 64 pixel, simultaneous readings
mV Accuracy: 1 mV
mV Resolution: 1 mV
Operating Temperature: 0 to 50 °C
ORP accuracy: 1 mV mV
Parameter: pH, mV, ORP/Redox, Conductivity, TDS, Salinity, Resistivity, Temperature
PC Data Transfer Software: -
pH Accuracy: ≤ 0.02 pH (± 1 digit)
Portable: Yes
Salinity accuracy: ≤ 0.5 % (± 1 digit)
TDS Accuracy: ≤ 0.5 % (± 1 digit)
Warranty: 3 years
Weight: 0.66 lbs. (0.3 kg)

 

HQ440d Benchtop Meter Package
Description

Designed for water quality experts, the Hach HQ440d benchtop meter ...see more

Specification

 

BOD5/CBOD resolution:Available when used with Hach WIMS BOD Manager software
Cable resistance correction:Digital - not needed
Calibration curves display:Calibration summary data logged and displayed
Data Export:Download via USB connection to PC or flash memory device.
Automatically transfer entire data log or as readings are taken.
Languages:English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Sweedsh, Czech, Russian
PC Data Transfer Software:Included
pH Measurement at stable reading:5 stabilization settings
Printer:Optional accessory
Salinity Resolution:0.01 ppt
Warranty:3 years
ITM 3
Description
  • Phase separation of products (for example whey – cream – milk)

  •  ...see more
Specification

 Features:

 

  • Hygienic front-flush sensor

  • No color dependency (wave length 860 nm)

  • Smallest pipe diameter: DN 25

  • Four measurement ranges, two externally switchable

  • High reproducibility: ≤ 1 % of full scale

  • Switching output (switchpoint and hysteresis free adjustable)

  • Analog output 4...20 mA (standard)

     

ITM-4
Description

 

Specification

The ITM-4 measures turbidity using the 4-beam alternating light method. The transmitter contains two infrared senders and two infrared receivers arranged at right angles to each other. To determine the turbidity value, the senders are alternately activated. When sender 1 is active, receiver 1 detects the transmitted light and receiver 2 detects the light scattered at 90°. When sender 2 is active, the situation is reversed. An exact turbidity value is calculated from the four measured values of a measurement cycle. Since a transmitted light measurement is available as a reference for each 90° scattered light measurement, interference factors such as contamination of the optics or component ageing can automatically be compensated. Disturbing infl uences from the sporadic occurrence of solids and air bubbles are largely cancelled out due to the evaluation of multiple measurement cycles.

Sonatax sc with SC200 Controller
Description

Optimize slud ...see more

Specification

Accuracy: 0.1 m

Cable Length:10 m (optional extension cables available)

Material: POM

Measuring Principle: Ultrasonic measurement

Operating Conditions (Temperature): 0 to 50 °C

Resolution: 0.03 m

TitraLab Automatic Titrator
Description

The TitraLab automatic analyzer is specifically designed for salt  ...see more

Specification

 Burette motor resolution: 40000
Languages: Spanish, English, French, Italian
Reagent: HNO3 1M
Titrant: AgNO3 0.1M
Unit: %NaCl, %Cl-

Hach TNTplusTM Vial Chemistries
Description

 

 ...see more
Specification

 

  • Easy and safe Dosi-Cap Zip - freeze-dried reagent integrated into sealed cap

  • Narrow neck minimises chance for reagent spills

  • Vials are colour-coded by parameter and range for easy recognition and error elimination

  • Barcode makes testing hand-free and fast-instrument automatically detects and runs the correct method

  • Flat bottom - improves handling, vial stands on its own

  • Optically superior glassware


Video: http://bcove.me/hkukusta

CL17 Total Chlorine Analyser
Description

Industry standard, CL17 Total Chlorine Analyzer. Included with the ...see more

Specification

Accuracy: ± 5 % or ±0.03 mg/L (ppm) as CL2, whichever is greater
Air Purge: N/A 0.1 cfm 20 psig instrument quality air at: maximum
Alarm: Relay Outputs
Certification: approved
Certifications 2: certified to CSA 22.2 No. 142
Cycle Time: 2.5 minutes
Depth: (13.5 x 16.5 x 7.5 in.)
Dimensions Metric (H x W X D): 16.5 in x 12.5 in x 6.7 in (419 mm x 318 mm x 171 mm)
Display: LCD, 3 digit measurement readout and six-character alphanumeric scrolling text line
Enclosure Rating: ABS plastic, two clear polycarbonate windows, IP 62 rated with the gasketed door latched
Inlet: polyethylene tube, quick-disconnect fitting
Interferences: Other oxidizing agents such as bromide, chlorine dioxide, permanganate and ozone will cause a positive interference. Hexavalent chromium will cause a positive interference:
1 mg/L Cr6+ = approximately 0.02 mg/L as Cl2.
Hardness must not exceed 1,000 mg/L as CaCO3. Light Source: Class 1 LED (light emitting diode) with a peak wavelength of 520 nm; 50,000 hours estimated minimum life
Lower Limit of Detection (LOD): 0.03 mg/L (ppm)
Mounting: Wall mount Operating Conditions (Temperature): 5 to 40 °C (41 to 104°F)
Operating Humidity: 90% at (90% at 104°F) maximum 40 °C
Power Requirements: 100-115 / 230 V AC, 50/60 Hz (switch selectable), 95 VA maximum, 2.5 Amp fuse
Precision: 3% or 0.01 mg/L (ppm) as CL2, whichever is greater
Pressure Limit: Inlet Pressure to Sample Conditioning 1.5 bar
Range: 0 - 5 mg/L free or total residual chlorine
Ranges: 0 - 5 mg/L free or total residual chlorine
Sample Flow Rate: 200 - 500 mL per minute minimum required
Sample Temperature: 5 to 40 °C (41 to 104°F)
Weight: 24.91 lbs. (11.3 kg)

 