410 ORBISPHERE controller with K1100 Luminescent Oxygen Sensor (Kit) - Panel
|
|
|
|
| Specification |
|
One calibration per year
One zero point calibration per year is all that is needed with the K1100 sensor, unlike traditional electrochemical (EC) sensors, which display significant drift after only a few months and demand regular re-calibration and substantial operator time.
No Membranes = 5 Minutes of Maintenance
Low Cost Retrofit for existing Orbisphere EC sensor
The complete system consists of a 410 Controller, a flow chamber and the K1100 Luminescent Dissolved Oxygen Sensor. The sensor is compatible with Hach Orbisphere 28 mm flow chambers previously used with EC sensors.
The K1100 optical sensor is the first to use luminescent measurement technology to measure low level oxygen in power plants. Since 1978, when the first patent on EC sensors was granted, Hach Orbisphere sensors have set the industry standard for oxygen measurement at ppb level.
|
|
|
|
FP360sc Oil-in-Water Sensor
|
|
|
|
| Specification |
|
Ambient Temperature:-5 to 45 °C (23 to 113 °F)
Cable Length:40 m (130 ft)
Detector:UV photodiode with interference filter; Compensation of daylight and flashlamp intensity fluctuations
Light Source:Miniature xenon flashlamp with interference filter
Measurement Method:UV fluorescence method for polycyclic aromatic hydrocarbons (PAH)
Reproducibility:2.5 % of measured value at constant temperature
(PAH)
Resolution:0.1 ppb (µg/L) (PAH) in the lowest measuring range
Response time T90:10 s
Sample Temperature:1 or 40 °C (33.8 to 104 °F)
Weight:Stainless Steel: 6.2 lbs or 2.8 kg
|
|
|
|
Hach Orbisphere 6110 Total Package Analyzer
|
|
|
| Description |
|
Easily and automatically provides oxygen and carbon dioxide concentrations for both the headspace ...see more |
|
| Specification |
|
Analysis Time: Approximately 4 minutes
Interface: digital connections:1 x USB client, 1 x USB host, 1 x Ethernet
Interface: digital display:TFT VGA (640 x 480) color touch screen
Interface: operating system:Windows® CE 4.2
Operating range: Package Temperature: -2 to 30°C (28 to 86°F) Package Pressure: 1.4 to 6.8 bar (20 to 73 psia) Ambient Temperature: 0 to 40°C (32 to 104°F)
Power Requirements:100/240 Vac ±10 %, 50/60 Hz
Range: O2: 7 ppb to 12 ppm CO2:0.75 to 5 v/v or 1.5 to 10 g/kg
Repeatability: TPOϯ: ±5 µg/L ±10 % whichever the greater CO2: ±0.05 v/v or 0.10 g/kg ±2 %, whichever is greater, measured on equilibrated packages at 10 to 25 °C
Weight: 55 kg (121 lb.)
|
|
|
|
|
|
|
|
|
|
|
|
AutoCAT 9000 Chlorine Amperometric Titrator
|
|
|
| Description |
|
Automatic calculation of analyte concentration. Aut ...see more |
|
| Specification |
|
Dimensions (H x W X D): 15 in x 9.1 in x 17.7 in (380 mm x 230 mm x 450 mm)Display Real-time graphics, menu driven, LCD
Electrode: Dual platinum
Languages: English, French, and Spanish
Output: RS-232 Serial output to printer/PC
Power Requirements: /264 Vac, 47/63 Hz, 115 VA
Width US: N/A
|
|
|
|
|
|
|
|
|
|
|