AUSTRALIA NEW ZEALAND
Phone: 1300 8877 35 Phone: 0800 50 55 66
Phone: +61 3 9545 6229 Phone: +64 9 579 0141
 
 
Product Search
Keywords:
Product Category:
for more hach products

 go to www.hach.com

Request your Catalogue

 

Upcoming Events

 

 

Australia 

 2012 WIOA VIC

75th Annual Victorian Water Industry Engineers and Operators Conference
5 & 6 September 2012
Bendigo, Victoria
 

 

New Zealand
 
2012 Water New Zealand Conference and Expo

26 - 28 September 2012
Rotorua Energy Events Centre

2012 Food Tech Pack Tech Conference
25 - 27 September 2012
ASB Show Grounds, Greenlane, Auckland

 

 
410 ORBISPHERE controller with K1100 Luminescent Oxygen Sensor (Kit) - Panel
Description

The Orbispher ...see more

Specification

 

One calibration per year

One zero point calibration per year is all that is needed with the K1100 sensor, unlike traditional electrochemical (EC) sensors, which display significant drift after only a few months and demand regular re-calibration and substantial operator time.

No Membranes = 5 Minutes of Maintenance

Low Cost Retrofit for existing Orbisphere EC sensor

The complete system consists of a 410 Controller, a flow chamber and the K1100 Luminescent Dissolved Oxygen Sensor. The sensor is compatible with Hach Orbisphere 28 mm flow chambers previously used with EC sensors.

The K1100 optical sensor is the first to use luminescent measurement technology to measure low level oxygen in power plants. Since 1978, when the first patent on EC sensors was granted, Hach Orbisphere sensors have set the industry standard for oxygen measurement at ppb level.

Hach Orbisphere 6110 Total Package Analyzer
Description

Easily and automatically provides oxygen and carbon dioxide concentrations for both the headspace ...see more

Specification

Analysis Time: Approximately 4 minutes

Interface: digital connections:1 x USB client, 1 x USB host, 1 x Ethernet

Interface: digital display:TFT VGA (640 x 480) color touch screen

Interface: operating system:Windows® CE 4.2

Operating range: Package Temperature: -2 to 30°C (28 to 86°F) Package Pressure: 1.4 to 6.8 bar (20 to 73 psia) Ambient Temperature: 0 to 40°C (32 to 104°F)

Power Requirements:100/240 Vac ±10 %, 50/60 Hz

Range: O2: 7 ppb to 12 ppm CO2:0.75 to 5 v/v or 1.5 to 10 g/kg

Repeatability: TPOϯ: ±5 µg/L ±10 % whichever the greater CO2: ±0.05 v/v or 0.10 g/kg ±2 %, whichever is greater, measured on equilibrated packages at 10 to 25 °C

Weight: 55 kg (121 lb.)

 