AUSTRALIA NEW ZEALAND
Phone: 1300 8877 35 Phone: 0800 50 55 66
Phone: +61 3 9545 6229 Phone: +64 9 579 0141
 
 
Product Search
Keywords:
Product Category:
for more hach products

 go to www.hach.com

Request your Catalogue

 

Upcoming Events

 

 

Australia 

 2012 WIOA VIC

75th Annual Victorian Water Industry Engineers and Operators Conference
5 & 6 September 2012
Bendigo, Victoria
 

 

New Zealand
 
2012 Water New Zealand Conference and Expo

26 - 28 September 2012
Rotorua Energy Events Centre

2012 Food Tech Pack Tech Conference
25 - 27 September 2012
ASB Show Grounds, Greenlane, Auckland

 

 
AutoCAT 9000 Chlorine Amperometric Titrator
Description

 

Automatic calculation of analyte concentration. Aut ...see more

Specification

 Dimensions (H x W X D): 15 in x 9.1 in x 17.7 in (380 mm x 230 mm x 450 mm)Display Real-time graphics, menu driven, LCD
Electrode: Dual platinum
Languages: English, French, and Spanish
Output: RS-232 Serial output to printer/PC
Power Requirements: /264 Vac, 47/63 Hz, 115 VA
Width US: N/A

Biogas Titration Manager
Description

Biogas Titration Manager for efficient routine analysis process ac ...see more

Specification

Beaker Volumes Accepted: 5 to 400 mL

Burette: Motor Resolution: 18000 steps
Burette: Stand / Tap Type: 1 x 25 mL embedded burette stand included
Burette: Volumes Available: 1 mL, 5 mL, 10 mL, 25 mL & 50 mL
Dimensions (English Units): 18 in x 9 in x 15 in Display: LCD: Graphic 128x128 dot LCD protected from spillages w/TPX cover
GLP Features: Automatic GLP compliant result printouts with optional printer connected Input: Electrode and temperature
PS/2 port for optional PC keyboard and/or barcode reader Languages of User Interface: English, German, Danish, French, Italian, Spanish, Swedish
Measurement Method:
FOS/TAC ratio according to Nordmann method:
-Total Inorganic Carbon TAC
-Volatile Organic Acids FOS
Combined pH & FOS/TAC Measurement Range: -2000 to +2000 mV
mV Resolution: 0.1 mV
Operating Humidity: 20 to 80 % (without water condensation)
 Operating Temperature: 5 to 40 °C
Output: Serial connections printer/PC, balance, sample changer, and additional titrator for use with TitraMaster 85 PC software Password Protection: Up to 10 characters, alphanumeric pH Direct
Measurement: -9 to 23 pH pH Resolution: 0.001 pH Power Requirements: 115 Vac (+/-10%) or 230 Vac (+/- 10%), 50-60 Hz
Sample Changer: Serial RS232 with SAC850
Sample ID: Up to 16 characters, alphanumeric
Sample Stand: Embedded with magnetic stirring Stirring Speed: 0 to 1100 rpm in 50 rpm steps, optional propeller stirrer available
Stored Data: Non-volatile memory storage of the last 60 results & last reagent/electrode calibration
Stored Programs:
Up to 10 user-programmable methods including preprogrammed methods.
Non-volatile memory for storage of last 60 results & last reagent/electrode calibration.
Embedded operating prodecures for burette daily maintenance and reagent exchange operations.
Temperature Range: -10 to 100 °C Temperature Resolution: 0.1 °C TTL Input / Output: 1 Input/1 Output 0-5V
Unit:
Equivalent volumes at end point
TAC in mg/L CaCO₃ (lime reserve)
FOS in mg/L CH₃COOH (acetic acid)
FOS/TAC ratio User ID: Up to 16 characters, alphanumeric Weight: 5 kg (excluding reagent bottles)
User ID: Up to 16 characters, alphanumeric
Weight: 5 kg (excluding reagent bottles)
TitraLab Automatic Titrator
Description

The TitraLab automatic analyzer is specifically designed for salt  ...see more

Specification

 Burette motor resolution: 40000
Languages: Spanish, English, French, Italian
Reagent: HNO3 1M
Titrant: AgNO3 0.1M
Unit: %NaCl, %Cl-

 